Defibrillator Monitor

Introduction of the Portable defibrillator monitor:

Defibrillation device, which can meet your clinical needs from Basic Life Support (BLS) to 

 

Advanced Cardiac Life Support (ACLS).  

 

 Specifications of the Portable defibrillator monitor:

 

Display:

Screen Type: High-resolution display

Screen Size: 8 inches diagonally

Sweep Speed: 25mm/sec

Information: Heart Rate, Lead/Pads, Alarm On/Off, SpO2, AED Functions and Prompts, Alarm Selection and Limits, Delivered Energy.


Defibrillator:

Waveform: Biphasic

Charge Time: Less than 7 seconds with a new fully charged battery.

Energy Display: Monitor display indicates both selected and delivered energy.

Charge Prompt Type: Voice and visual prompts.

Electrode Impedance Measurement Range: 0-250 ohms.


ECG Monitoring:

Patient Connection: 3-lead ECG cable, or 5-lead ECG cable, paddles.

Lead Selection: Displayed on monitor, paddles, I, II, III, AVR, AVL, AVF, V.

ECG Size: 0.25, 0.5, 1, 1.5, 2, 4 cm/mV diplay on monitor.

Heart Rate: 20-300BPM.

Heart Rate Alarm: On/Off displayed on monitor, user-selectable.

Smart Alarms: Beeper/voice prompts indicate shockable rhythm.


Battary:

Type: Rechargeable, Ni-MH battery, 12V.

Operating Time: For a new, fully charged battery: 60 defibrillator discharges at maximum energy, or 3 hours minimum of continuous ECG monitoring. Additional parameters will effect operating time with different functions.


Storage: standard memory card 4G or greater memory 


SpO2 Module:

Measurement Range: 30~100%, ± 2% between 80%~90%, others ± 5%

Alarm Range: User set high limit and low limit.

Alarm Accuracy: ± 10% within setting values.

Alarm time Accuracy: Less than 12 sec.


Recorder:

Paper: 50mm thermal.

Speed: 12.5mm/sec, 25mm/sec, 50mm/sec. User-selectable 6-second delay.

Printing Method: High-resolution, thermal print head.

Print-out Modes: Manual or automatic, user-configurable.

On/Off Control: Front panel and paddle.

Automatic Function: 9-seconds recording initia